  • With true double-conversion design, provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It''''s perfect protection for your precisous servers and workstaiosn.
     
    Outstanding Features
    ◆LCD PANEL
    ◆ Cold start
    ◆ Zero Conversion
    ◆ Automatic restart
    ◆ Beeping Selection
     
    ◆DSP,IGBT,PFC Technology
    ◆Green and Environment-friendly
    ◆ 0.8 Load power factor
    ◆ Intelligent LCD Display(Optioanl)
    ◆ Automatic recharge even UPS is off
    ◆ Intelligent Battery Management (IBM)
    ◆ Beeping Alarm on Battery, Battery Low and Overload
    ◆ Automatic Adjustment to 50Hz/60Hz Power Supply System
    ◆ Strong Expansion Function,Webpower,AS400,RS485 card could be installed.

  • Technical Spec
    Model
    Item
    RDNU6K RDNU6KL RDNU10K RDNU10KL RDNU3110-CX RDNU3115-CX RDNU3120-CX
    Rated power 6000VA/4800W 10kVA/8KW 10kVA/8KW 15kVA/12KW 20kVA/16KW
    AC INPUT
    AC Input Input system Single phase & earth ground
    Range voltage 200,220,230,240VAC 380VAC
    Frequency 50/60Hz
    Voltage range 115~300VAC±5 @ half load; 176-296VAC±5 @ full load
    Frequency range 45~55Hz±0.5Hz or 55~65Hz±0.5Hz auto sense
    Voltage range of bypass 65VAC×(1±5%)~140VAC×(1±5%)
    BATTERY INPUT
    Battery Input Type Lead-Acid maintenance-free
    Voltage range of battery 192/240VDC optional
    Bat Number 16/20PCS optional
    Inside batteries 12V7AH - 12V7AH -
    Backup Time Standard ups: Half loaded≥10minutes,Full loaded ≥5minutes
    Long backup ups: depend on external batteries
    Charging current 1A 6A/8A optional 1A 6A/8A optional
    Battery charged time Standard ups: Charger to 90% battery capacity in 5 hours
    Long backups ups; Depend on the capacity of external batteries
    AC OUTPUT
    AC Output Output system Single phrase & earth ground
    Output voltage 220±1%(inverter output)
    Output frequency 50±5Hz(line normal, according to line) 50Hz±1%(line abnormal)
    Dynamic voltage transient range <5%
    Dynamic transient restore < 60ms
    Waveform Sine Wave THD<3%(linear load) ;Sine Wave THD<8%(nonlinear load)
    Power factor 0.8
    Overload capability 105~125%≥ 60s,126~150%≥30s The recovery point is 90%
    Current peak coefficient 3:1
    Transfer time 0ms (line and battery)
    < 4ms(line bypass bypass)
      Efficiency 90%
    : THD <2%
    INTERFACE
    Interface LCD or LED Panel I/P Voltage, I/P& Frequency,Battery voltage,UPS status, load, temperature,O/P Voltage,Frequency, B/P Voltage,Frequency
    Communications RS232,Intelligient Slot (Web power card, or As400 Card Optional).
    FUNCTION
    Function Cold start DC Power On
    Automatic Charge Automatically Charge when UPS is off
    Automatic Restart Automatic Restart if main power coming after battery mode shutdown
    Frequency 50HZ/60HZ Auto Adjustable
    Alarm AC/DC input under abnormal ,overload condition and inverter problems
    Protection AC input or output above or below the range of voltage Overload ,over temperature and short circuit protection
    ENVIRONMENT
    Environ-ment Temperature -10~40 degree
    Humidity 20% to 90%
      Noise level ≤55dB
    PHYSICAL CHARACTERISTICS
    Physical Net Weight (KGs) 58 17.92 59.5 19.52
    Gross Weight (KGs). 67 21 68.5 22
    Product Dimensions (L*W*H* mm) 500*250*615 500*240*450 500*250*615 500*240*450
    Packing Dimensions (L*W*H* mm) 675*375*850 610*410*610 675*375*850 610*410*610