  • C series UPS designed to withstand high fluctuation power. Built-in input OVCD, it becomes a rugged UPS to protect your equipment against extreme high voltage. Besides, charger can be expandable to 8A for long-run model by request.
     
    Main Features
    o    True double-conversion
    o    Microprocessor control optimizes reliability
    o    Input power factor correction
    o    Output power factor 0.8
    o    Wide input voltage (110 V – 300 V)
    o    Converter mode available
    o    Generator compatible
    o    Charger capacity expansion to 8A for long-run models
    o    Smart SNMP works well with either USB or RS-232 together
    o    Comprehensive display allows easy monitoring and access of UPS status

  • Model RDNU1K RDNU1KL RDNU2K RDNU2KL RDNU3K RDNU3KL
    Rated power 1000VA/800W 2000VA/1600W 3000VA/2400W
    AC Input Input system Single phrase & earth ground
    Range voltage 210/220/230Vac
    Frequency 50/60Hz
    Voltage range 115~300VAC±5@half load; 176-296VAC±5@full load
    Frequency range 45~55Hz±0.5Hz or 55~65Hz±0.5Hz auto sense
    Power factor 0.99
    Voltage range of bypass 65VAC×(1±5%)~280VAC×(1±5%)
    Battery Input Type Lead-Acid maintenance-free
    Voltage range of battery 36VDC(24V/48Voptiona) 72VDC(48V/96VOptional) 96VDC
    (48V/72VOptional)
    Bat Number 3(2/4 optional) 6(4 /8 optional) 8(4/6 optional)
    Inside batteries 12V7AH - 12V7AH - 12V7AH -
    Backup Time Standard ups: Half loaded≥10minutes,Full loaded ≥5minutes
    Long backup ups: depend on the external batteries
    Charging current 1A 7A 1A 7A 1A 7A
    Battery charged time Standard ups: 5 hrs to 90% battery capacity
    Long backups ups; depend on the capacity of external batteries
    AC Output Output system Single phrase & earth ground
    Output voltage 210/220/230Vac±2%
    Output frequency 50±5Hz(line normal, according to line)   50Hz±1%(line abnormal)
    Dynamic voltage transient range <5%
    Dynamic transient restore < 60ms
    Waveform True sine wave
    Power factor 0.8
    Overload capability 105~125%≥ 60s,126~150%≥30s The recovery point is 90%
    Current peak coefficient 3:1
    Transfer time 0ms (AC to DC)
    < 4ms(AC to Bypass)
    Efficiency 85% 88%
    THD <2% full load(linear load)
    Panel display LCD and LED  I/P Voltage, I/P& Frequency,Battery voltage,UPS status, load, temperature,O/P Voltage,Frequency, B/P Voltage,Frequency 
    Interface Communications RS232,Intelligent Slot (Web power card, or As400 Card Optional),Dry contacts optional
    Power Outlets No. and types 2  SOCKETS 4 SOCKETS 3 SOCKETS and 1 terminal
    Function Cold start DC Power on
    Automatic Charge Automatic Charge when UPS is off
    Automatic Restart Automatic Restart if main power coming after battery mode shutdown
    Frequency 50HZ/60HZ Auto Adjustable
    Alarm AC/DC input under abnormal ,overload condition and inverter problems
    Protection AC input or output above or below the range of voltage Overload ,overtemperature and short circuit protection
    Environment Temperature    -5 to 45 Degree
    Noise level ≤55dB
    Humidity        20% to 90%
    Physical Weight (KGs) 11.5 5.5 22 10 27 11
    Shipping Wt. 12.5 6.6 24.5 12.5 29.5 13.5
    Net dimensions (L*W*Hmm) 345*145*230 420*190*335
    Gross dimensions (L*W*Hmm) 430*240*340 550*350*490